- Heathkit SA-2060A 4:1 Balun
- Estimate core as two T200-2 Powdered Iron with 14 Turns
T200-2 AL = 120uH/100T (Reference)
Two T200-2 AL = 120uH * 2 = 240uH
uH = 240 * (14/100)2 = 4.7uH
- C1.Wr1M = Estimated wire loss at 1MHz
14T #16, 2.23Ω/100' at 1MHz
(Reference)
Length=45" (estimated)
2.23 / 100 / 12 * 45 = 0.0836Ω (Round up to 0.1Ω)
- Estimated core loss, Rp = 80kΩ, using T94-2 measurement below
- Balun measurement, Balun.s1p, from ZL4AI using AA-54, photo below
- Square chart L dBW = Balun Matched Loss
- Files: ZL4AI.zip
|
SimSmith SA-2060A 4:1 Balun Model and Measurement
ss-Balun-Auto.ssx
SimSmith Balun Model RUSE
Photo by ZL4AI
Evaluate -2 Powdered Iron Loss
Wire Resistance
|
- 24T #22, 4.73Ω/100' at 1MHz
(Reference)
- Length=26" (measured)
- 4.73 / 100 / 12 * 26 = 0.1025Ω
|
SimSmith T94-2 Core Loss Estimate
ss-T94-2-24T-S.ssx
SimSmith Inductor RUSE
T200-2 14T 4:1 Auto-Transformer
SimSmith Description
|
---|
- C1 Auto-Transformer RUSE, Parameters tuned to match VNWA measurement
- S1.File = T200-2-14T-Auto.s2p (12-term correction VNWA measurement)
- Files: ZL4AI.zip
|
SimSmith Auto-Transformer Model and VNWA Measurement
ss-T200-2-14T-Auto.ssx, useZo
SimSmith Auto-Transformer Model and VNWA Measurement
ss-T200-2-14T-Auto.ssx, xMtch
SimSmith Auto-Transformer RUSE